Monitoring your battery bank is easy with the Battery Monitor Kit (ME-BMK)* from Magnum Energy. Acting as a ?fuel gauge? for your batteries, the ME-BMK monitors their state of charge (SOC) and then provides this information in an easy-to-understand display via the ME-RC remote. With accurate SOC readings, you can avoid unneccessary battery recharging, saving on fuel and long-term maintenance costs.
If you already have a Magnum Inverter/Charger and Magnum Remote*, the ME-BMK is an easy retrofit. Simply install the kit according to the installation manual and begin monitoring your battery bank via the ?Meter? button on your ME-RC.
Available readings from the ME-BMK
-
State of Charge (SOC)
-
0 - 100%
-
DC volts
-
DC amps
-
Amp hours in/out
-
Resettable amp hours out
-
Total amp hours out
-
Minimum volts DC
-
Maximum volts DC
-
Temperature compensated
- Auto detects input voltage
ME-BMK
DC volts 7 to 70 (±0.5%) auto voltage detection
DC amps ±0.1 to 999 (±1.0%)
Battery SOC % 0 to 100% (1% increments)
Power draw < .6 watts
Amp hours in/out ±32,768 amp hours (1 AH increments)
rAH out (resettable amp hours removed) 0 to 65,353 amp hours, resettable (0.1 AH increments)
tAH out (total amp hours removed) 0 to 65,535,000 amp hours (0.1 k or 100 AH increments)
Minimum/maximim DC 7 to 70 VDC, resettable
Shipping weight 2 lb (.9 kg)
Kit includes Manual, sense module, DC shunt, twisted pair wire, and communication cable
Sense wire Twisted pair ?blue & orange, 5? length, 18 AWG wire
Communication cable 2-conductor, 10? twisted pair, telephone standard
Remote requirements Use with an ME-RC with firmware revision of 2.0 or higher
DC Shunt
Resistance 0.1 milliohm (500A at 50mV)
Continuous current 410 amperes maximum
Overload current Overloads to 500 amps for less than 5 minutes if normally operated at less than 300 amps